May give you a more pleasing installation much less expensive too. You can do it, just be patient and do your homework. This low voltage underwater light transformer is normally designed with a cord and plug connection on the primary of that low voltage transformer designed to plug into a normal single plug-in type weatherproof receptacle installed as a dedicated branch circuit to serve that low voltage underwater pool light transformer.


The hose making the pump and filter to be remote from the pool would be much cheaper than the outside wiring with the pool pump and filter installed next to the pool. I never heard of this but would be interested to see what he has to say. Talking to your AHJ [electrical inspector] may save you some heartache in rewiring what you just wired if in a questionable situation concerning the NEC rules. Regardless whether your motor circuit is volt rated or volt rated the distances still apply the same. There are at least a few every year.

To view the twist lock style receptacle you may click on the picture icon to the left. Leave a Reply Cancel reply Your email address will not be published. The hose making the pump and filter to be remote from the pool would be much cheaper than the outside wiring with the pool pump and filter installed next to the pool. A pool can not be installed inside a structure of any kind, and meet the NEC definition of a storable pool. Just remember to remove you hoses and let them drain to winterize our plumbing same as people do with in-ground pools. Please make yourself a rule always to remove that portable ladder from the pool, when the pool is not in use, electrical hook up above ground pool. The pump amp draw is max What is the amp usage on the motor label? That underwater pool light transformer may also be served by a specially wired pool type sub-panel in an new accessory building fed from the main service rated panel as a common service from the main house to this new pool type sub panel containing four insulated feeder wires serving that new pool type sub-panel including an insulated equipment grounding conductor ran with the feeder to serve that new pool type sub-panel. The branch circuit serving an underwater pool light must not be served in any manner by a nonmetallic sheathed cable [aka Romex] or UF cable, whether installed while inside or installed while outside the dwelling structure. Is this type of grounding really necessary? What is HP your pool pump? A white conductor must not be used as a hot conductor if this white conductor is not contained within a nonmetallic sheathed cable. I have a filter pump and a saltwater system both with gfi cords but only have one outdoor outlet. Enter Your Zip Code: I recommend only using an extension cord temporarily until you can have a permanent power line buried that runs to the pump. The conductors must be single conductors and insulated including the 12 awg copper equipment grounding conductor. This receptacle must be GFI protected. The receptacle must be a single plug-in style receptacle, weather proof, with a bubble shield weatherproof in-use receptacle plate. Why do think you need a ground rod? Again the breaker must be listed for use in your brand and model of panel that you have. It seemed to me that I was always building pools way out in the boonies. Matthew, you replied to my post on August 10,but your pump motor wire gauge ukraine free dating site does not display? See an example by clicking on the picture icon to the left. Concerning a pool motor, allowed by the NEC, while the wiring is inside the house concerning a pool motor, you may use a nonmetallic sheathed cable NEC Article Unless with a transformer and a low electrical hook up above ground pool underwater light with the junction box installed prior to the placement of the transformer in the underwater pool light branch circuit, a junction box specifically approved for the purpose for use on an underwater pool light branch circuit must be with green grounding screws in that junction box equal in number plus one more grounding screw in excess of the number of conduit entries manufactured in that underwater pool light junction box. The reality is when there is an electrical fault or difference in potential it can become deadly. Can I use a Honda generator to run the over ground pool pump and if so is a ok? You may refer to the following link showing an example of a weatherproof bubble shield receptacle required to be used to serve this pool approved low voltage transformer cord and plug connection design; click on the picture icon to the left. Now if you ran a 12 awg copper 20 amp or preferably a 10 awg 30 amp rated volt feeder to a 4 circuit weather proof sub-panel using a black, red, and 12 awg green wire to serve that sub panel as required by the NEC for pool sub panels NEC Article

I remember it well. Using just a map, I drove way out to the other side of Lake County to a small house that looked like a shack, electrical hook up above ground pool. It seemed to me that I was always building pools way out in the boonies.

And it was always the last house on the right. As you can imagine, this place was way out in the middle of nothing. When I arrived, I was still unaware that they had no electricity and started asking the standard questions of where did they want the pool and where did they want the pump and filter.

He had no idea that a pool has to have a pump and filter. After I explained it to him, he of course wanted me to install the pool anyway and said that he would just have to figure it out later. Now of course electricity is everywhere. Above ground swimming pools come with above ground pool pumps. I say this because pumps for in-ground pools are a little different. Since pumps for above grounds only come as V, they all have standard three-prong plug cords attached to them.

So due to these pumps having standard cords on them, the easiest way to get power to your pool is to use an extension cord connected to some outlet from the house, electrical hook up above ground pool. I recommend only using an extension cord temporarily until you can have a permanent power line buried that runs to the pump. Many only use an extension cord as theymay not have the money to do it right.

If this is the case for you, then use an extension cord that has at least a 12 gauge wire. You really want a 10 gauge, but these cords are pricey. You want a thicker extension cord, because a pool pump requires a good amount of electricity to run. So, if the wire in the extension cord is too thin then the cord can eventually burn up or overheat causing the pump not to run.

Your pool pump is greedy. If it shares the electricity with something else, it may cause the breaker to throw off. Well, not too scary. Find out how many amps the pool pump needs Amperage is the amount of electricity that runs through the electric wires. You need to know this for two reasons. A typical above ground pool pump will require a amp breaker and use 12 gauge wire to deliver the electricity. Does your swimming pool have any other electrical needs? Your swimming pool equipment may have other needs for electricity.

Add-ons like ozonators, ionizers, and salt chlorine generators require electricity. If these add-ons are made for above grounds then they usually have standard three-prong plugs so you want to make sure there is an outlet for them.

Above ground pool lights will also need an outlet. NEC is the acronym for National Electric Code and it can be found online or by calling your local building department or talking to an electrician. The NEC will tell you things like how far down to bury the wires, the wire size, breaker size, which weatherproof outlet to use, rehydroxylation (rhx) dating of archaeological pottery grounding requirements.

A timer will do this automatically. Believe me, getting a timer is worth the extra money and hassle. The electrical component of an above ground swimming pool is pretty important. If you have any questions on your above ground pool services then we would be happy to help, feel free to give us a call at or email us at upload inyopools.

What is the amp usage on the motor label? Also, what is the distance between the light source and the pump? My carlow dating sites pump will be located approximately from service panel.

Will a 1 hp pump be sufficient billings mt hookup a 20 amp circuit online dating body language 12 g wire for a 28ft pool. A generator could be used in place of an extension cord, but the engine sound and gas fumes could dampen pool fun for swimmers. Why do think you need a ground rod?

Matthew, you replied to my post on August 10,but your pump motor wire gauge guide does not display? Can you format differently or provide a link please? This was my original post. Yes, if you want safe pool equipment, ground or use a bonding wire. Step 10 on this guide explains how to bond a pump motor: I have a filter pump and a saltwater system both with gfi cords but only have one outdoor outlet.

Both want fit in same outlet. Can I use extension cord for one? And is it safe to have both in same outlet. Electrical hook up above ground pool it is safe as long as the outlet has a Gfci or Gfi as some call it. One thing which is essential for any outdoor installation or where dating site similar to tagged is water is an earth leakage breaker. They work by comparing the live and neutral currents in the cable and immediately disconnect the power if they are not the same.

This will prevent you being killed by electrocution as a result of a fault in the pump or other pool wiring because some current will flow to earth through the equipment or yourself resulting in an imbalance in Live and Neutral.

The RCD will detect this and immediately switch off the power before you are injured. Note that a RCD will not protect you if you shove your fingers into both the live and neutral power connections but it will protect you from most other conditions. If you are using a generator then you should use a ground rod to ensure that the system is properly earthed and to enable the RCD to detect faults.

Our building codes are pretty good though. That is dependent upon the HP of the pump. What is HP your pool pump? Also, is this running on or volts?

Real above ground pumps need at least a 12g cord. Hi Dan I had an electrician come out to give me an estimate on electrical work for my new above ground pool.

He mentioned putting in a copper ring around the pool and connecting that to each support pole on the pool then back to the pump. Is this type of grounding really necessary? He quoted me 3, I am in the same boat as you.

I heard that as well and we are planning on an above ground pool soon. I never heard of this but would be interested to see what he has to say. That sounds like a lot of money. Yes this is required by the national electrical code.

Note trenching holes can cost money. Grounding is a weird topic though. One whose opinions are mostly theoretical. Have a pool party instead with the money.

Yes, there are a lot of pools installed without bonding being installed properly. The reality is when there is an electrical fault or difference in potential it can become deadly. There are at least a few every year. Google Pool electrocution and you will find many articles. GFCIs and proper bonding can prevent these accidents. Also 1 hp converts to watts. My abg is about feet from my breaker panel. Do I need a disconnect switch between the pump outlet and the panel?

Also, how deep should I bury my circuit from the pump to the house, and do I need to put it in pvc? The pump amp draw is max I run a 10 gauge ground wire from the pump to the steel rod the to the ground lug on the chlorine generator.

There is a 20 amp circuit breaker for all the garage receptacles. Does this sound ok to do? Whatever It Takes Above ground swimming pools come with above ground pool pumps. Work some overtime and pay someone to do this. If you are running the motor on volts, gauge would work fine. Can I use a Honda generator to run the over ground pool pump and if so is a ok?

Will a 50ft 14 gauge extension cord work for a swimming pool pump. Leave a Reply Cancel reply Your email address will not be published. Pool Plumbing Valve Guide.


C Then up a 4x4 treated wood post to a two hole PVC weather proof device box screwed to the post about knee high. The pool must not be capable of containing water depth exceeding 42" or of metal sides or this pool would not meet the NEC definition of a storable pool. A duplex receptacle used on a normal branch circuit is allowed to be 15 or 20 amp rated even on a 20 amp branch circuit, but a single plug-in style receptacle that is required when used for a underwater pool light branch circuit must be rated in amps equal to the ampacity rating of the branch circuit. You may have a motor that is rated more than a 20 amp branch circuit. There is a 20 amp circuit breaker for all the garage receptacles. Bad part of this choice is that to move the motor in for the winter you will have to open the cover plate and unwire the motor connections inside the motor to move the motor inside for the winter. I am not trying to sell a product, just trying to show you a new product on the market that is an approved cable to do all the pool wiring needs from inside the home at the panel to the outside electrical hook up above ground pool underground to the pool pump motor. And is it safe to have both in same outlet. E and NEC Article An example of an inflatable pool that can be as deep or large around as you like and still be considered as a storable pool as long as it is not installed inside a wood deck, or underground, or inside a house can be viewed by clicking on the picture icon to the left. You may have a larger than expected horse power rated pool pump motor. Just check to make sure you have this remote filter option concerning your pool pump filter system, most do have that remote filter installation option. He quoted me 3, My pool pump will be located approximately from service panel. If you wish to install a receptacle whether it be volt rated or volt rated in the place of the switch or disconnect mentioned above, then you must move your pool pump motor so that pool pump motor cord required to have maximum length no more than 3 feet long motor cord NEC Article This single flexible nonmetallic sealtite type B conduit is all you would need to serve your pool, electrical hook up above ground pool, using one single type B nonmetallic sealtite flexible conduit containing the branch circuits serving the pool pump or pumps and the pool underwater light fixture or fixtures, as long as all branch circuits are GFI protected inside the conduit wherever the underwater pool light branch circuit is GFI protected installed within that same conduit. This 20 amp volt GFI breaker must be listed and approved for use in your brand and model of house electrical panel serving your house. Pool Plumbing Valve Guide. Grounding is a weird topic though. Remember that any branch circuit that is not over volts or over 20 amps and is GFI protected must be installed at least 12 inches deep. Remember that any direct buried wire must be a minimum of 24 inches deep. This is only true if there is no grounding path connecting the two buildings together either being a non-current carrying metallic path [such as a metal water pipe] or an equipment grounding conductor ran with the feeder connecting the two equipment grounding systems together. If a non-service rated panel [aka sub-panel] in an accessory building fed by a common service with the main building is fed by a feeder using a three wire feeder as allowed using NEC Article